SWP1

SWP1-16MMF SWP1-8MMF SWP1-8
Number of LAN ports (1000BASE-T/100BASE-TX/10BASE-T, etherCON connector) 12 8 8
Number of LAN ports (1000BASE-T/100BASE-TX/10BASE-T, RJ-45 connector) 4 - -
Number of SFP ports (1000BASE-SX, opticalCON connector) 2 (1 optical module is installed as standard) 2 (1 optical module is installed as standard) 2 (optical modules are not installed as standard)
Console port 1 (RJ-45) 1 (RJ-45) 1 (RJ-45)
Automatic negotiation Available Available Available
Auto MDI/MDI-X Available Available Available
Switching capacity 36 Gbit/s 20 Gbit/s 20 Gbit/s
Throughput 27 Mpps 15 Mpps 15 Mpps
Maximum number of MAC addresses 16,384 16,384 16,384
Frame buffer 1024 kB 1024 kB 1024 kB
VLAN Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN Port VLAN, Tag VLAN (IEEE802.1Q), Private VLAN
Maximum number of VLANs 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID. 256 (VLAN ID 1-4,094) *VLAN ID 1 is the default VLAN ID.
IP multicast IGMP Snooping (v1/v2/v3) IGMP Snooping (v1/v2/v3) IGMP Snooping (v1/v2/v3)
QoS 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR) 8 egress queues, Policy-based QoS, Remarking (CoS, ToS, DSCP), Scheduling (SP, WRR)
Flow control IEEE802.3x (Full-duplex), back pressure (Half-duplex) IEEE802.3x (Full-duplex), back pressure (Half-duplex) IEEE802.3x (Full-duplex), back pressure (Half-duplex)
Support functions Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP. Storm control, HOL blocking prevention, Loop detection, ACL, SNMP agents, Link aggregation (IEEE 802.3ad LACP, Static), Spanning tree (STP*, RSTP*, MSTP), Port mirroring, Port shutdown, Link speed down shift, Packet counter, Power saving mode (IEEE802.3az EEE; Disabled in DANTE mode), DHCP client, Logging, Firmware download via TFTP/HTTP, Config file download via TFTP *STP and RSTP are supported via downward compatibility of MSTP.
DIP switches CONFIG, VLAN PRESET CONFIG, VLAN PRESET CONFIG, VLAN PRESET
Indicators Front: POWER, LED MODE×4, PORT×16×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. Front: POWER, LED MODE×4, PORT×8×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN. Front: POWER, LED MODE×4, PORT×8×2*, SFP×2 *The LED MODE button allows the PORT lamps to be switched between indicating LINK/ACT-SPEED, STATUS, or VLAN.
Operating temperature 0 to 40°C 0 to 40°C 0 to 40°C
Storage temperature -20 to 60°C -20 to 60°C -20 to 60°C
Power supply (AC IN inlet) AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type AC100V-240V, 50/60Hz, Internal power supply (no power switch), Power supply inlet: locking type
Power supply (EXT DC INPUT inlet) External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector External power supply requirements: 24VDC±2V, 1A, XLR-4-32 type Connector
Maximum power consumption 16 W, 0.29 A 11 W, 0.21 A 11 W, 0.21 A
Heat dissipation 14.0 kcal/h 9.5 kcal/h 9.5 kcal/h
Chassis Metal case, no fan Metal case, no fan Metal case, no fan
Hazardous substances management RoHS compliant RoHS compliant RoHS compliant
Dimensions W 480mm 480mm 480mm
H 44mm 44mm 44mm
D 362mm 362mm 362mm
Peso 4.6 kg 4.2 kg 4.2 kg
Accessories Power cord, Owner's manual Power cord, Owner's manual Power cord, Owner's manual
Options MMF-SWP1 (Optical expansion unit), PA-700 (AC adaptor) MMF-SWP1 (Optical expansion unit), PA-700 (AC adaptor) MMF-SWP1 (Optical expansion unit), PA-700 (AC adaptor)

INTERFACE SPECIFICATIONS

Terminal Format Level Connector
1-8 *1 1-8, 13-16 *2 *3 IEEE802.3 10BASE-T/100BASE-TX/
1000BASE-T
etherCON CAT5e
9-12 *2 *3 IEEE802.3 10BASE-T/100BASE-TX/
1000BASE-T
RJ-45
9, 10 *4 17, 18 *5 *8 IEEE802.3 1000BASE-SX opticalCON
CONSOLE (RS-232C) - RS-232C RJ-45 *6
EXT DC INPUT - - XLR-4-32 type *7

*1 SWP1-8MMF, SWP1-8
*2 SWP1-16MMF
*3 These terminals support AutoMDI/MDI-X
*4 The SWP1-8MMF supports the option for port 10, and the SWP1-8 supports the option for both ports 9 and 10
*5 The SWP1-16MMF supports the option for port 18
*6 For the pin assignments, refer to CONNECTOR PIN ASSIGNMENTS
*7 Pin 4=+24VDC, pin 1=GND, pins 2 and 3=N.C.
External power supply requirements: 24VDC±2V, 1A
*8 Conforming cable: GI-type multi-mode fiber cables with a core diameter /cladding diameter of approximately 50 μm/125 μm.
Maximum cable length: 300 m

CONNECTOR PIN ASSIGNMENTS

CONSOLE (RS-232C)

Pin No. Signal
1 RTS
2 DTR
3 TxD
4 GND
5 GND
6 RxD
7 DSP *9
8 CTS *9

*9 These ports are not used on the SWP1.

Common Settings to Dante Mode

  • QoS (Quality of Service)
    • Enabled
  • QoS Trust Mode
    • DSCP
  • DSCP to Queue (*1)
    • DSCP:56 -> 7, DSCP:46 -> 5, DSCP: 8 -> 2, Others -> 0
  • EEE (Energy Efficient Ethernet)
    • Disabled

Preset Normal

  • Ports 1 to 8 (1 to 16)
    • Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
  • Ports 9/10 (17/18)
    • Access Port, VLAN 1, LAG On (sa1), STP On (*2), Loop Detection Off
  • VLAN 1 (for Dante)
    • IGMP Snooping: Enabled
      • Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
    • IPv4 Address: DHCP

Preset A

  • Ports 1/2, 5/6 (1 to 6, 9/10, 13/14)
    • Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
  • Ports 3/4, 7/8 (7/8, 11/12, 15/16)
    • Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
  • Ports 9/10 (17/18)
    • Trunk Port, VLAN 1/2, LAG On (sa1), STP On (*2), Loop Detection Off
  • VLAN 1 (for Dante)
    • IGMP Snooping: Enabled
      • Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
    • IPv4 Address: DHCP
  • VLAN 2 (for Others)
    • IGMP Snooping: Disabled

Preset B

  • Ports 1/2, 5 (1 to 6, 9/10, 13)
    • Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
  • Ports 3/4, 6 (7/8, 11/12, 14)
    • Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
  • Ports 7 to 8 (15 to 16)
    • Trunk Port, VLAN 1/2, LAG On (sa1), STP On (*2), Loop Detection Off
  • Ports 9 to 10 (17 to 18)
    • Trunk Port, VLAN 1/2, LAG On (sa2), STP On (*2), Loop Detection Off
  • VLAN 1 (for Dante)
    • IGMP Snooping: Enabled
      • Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
    • IPv4 Address: DHCP
  • VLAN 2 (for Others)
    • IGMP Snooping: Disabled

Preset C

  • Ports 1/2, 5/6, 9 (1 to 6, 9/10, 13/14)
    • Access Port, VLAN 1, LAG Off, STP Off, Loop Detection On
  • Ports 3/4, 7/8, 10 (7/8, 11/12, 15/16)
    • Access Port, VLAN 2, LAG Off, STP Off, Loop Detection On
  • VLAN 1 (for Dante Primary)
    • IGMP Snooping: Enabled
      • Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled
    • IPv4 Address: DHCP
  • VLAN 2 (for Dante Secondary)
    • IGMP Snooping: Enabled
      • Querier: Enabled (IGMP V3), Query Interval: 30 sec, Fast-Leave: Disabled

* The port numbers in parentheses refer to those on SWP1-16MMF.
*1 The DSCP to Queue settings are optimized for Dante.
*2 In order to activate Spanning Tree protocol (MSTP), you need to turn off Link Aggregation on the corresponding ports. You can download the Config files with Spanning Tree enabled here.

PA-700 AC Adapter

AC adapter for providing redundant power supply for SWP1, SWP2, RSio64-D, and DM7 Control.

  • Input power voltage: AC100-240V
  • Output power voltage: DC24V
  • XLR4-11C type connector
  • Dimensions: 139.0(W) x 31.3(H) x 58.2(D) mm *without cables